Browse all practice questions for the ESCO Heat Pump Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

ESCO Heat Pump Practice Test 2026 – Comprehensive Exam Prep course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What can you conclude about airflow in CFM if air velocity is measured at 400 FPM on a three-ton heat pump with a return grill of 3.4 square feet?
  • What type of water regulating valve must be used in a water source heat pump in heat mode?
  • In the heat mode, what does the suction line entering the compressor contain?
  • At 45°F ambient, how much more efficient can a heat pump system be compared to electric resistance heat?
  • Which type of heat pump does not require a defrost cycle?
  • What can terminate the defrost cycle in a heat pump system?
  • To make the reversing valve slide move, what pressure difference is necessary?
  • How can a lockout (impedance) relay be reset?
  • What must be calculated first to determine a heat pump's balance point?
  • As outdoor ambient air temperature decreases, what happens to a heat pump's COP?
  • What are the two mechanisms that can terminate defrost in a heat pump system?
  • What three actions typically occur during defrost in an air-to-air heat pump?
  • Which of the following are the main types of heat pumps?
  • What is the industry standard for the maximum duration of a defrost cycle in heat pumps?
  • In a service call for insufficient heat, if the suction pressure is higher and discharge pressure is lower than normal, and temperatures are measured, what does a discharge line temperature of 215°F indicate?
  • If a heat pump functions correctly in cooling mode but not in heating mode, what could be the likely issue?
  • Why is refrigerant management essential in heat pumps?
  • What is the purpose of a thermal expansion valve (TXV)?
  • What is another name for the reversing valve used in heat pumps?
  • What situation can occur if a crankcase heater fails in a heat pump?
  • Where does the low pressure refrigerant vapor go after leaving the reversing valve in cooling mode?
  • What does "SEER" measure in heat pump systems?
  • What is the status of the indoor metering device when the heat pump is operating in cooling mode?
  • How is SEER calculated in a heat pump system?
  • What initial temperature reading indicates a potential issue with indoor airflow in heat mode?
  • What occurs when registers in uninhabited rooms are closed while operating in heating mode?
  • What are common signs of a malfunctioning heat pump?
  • At temperatures above 45 degrees *F, what does the heat pump refrigeration cycle allow?
  • In a heat pump system, what component is essential for reversing the flow of refrigerant?
  • What is the primary function of the expansion valve in a heat pump system?
  • If the low side pressure is higher than normal and the high side pressure is lower than normal in heating mode, what is the most likely cause?
  • How does the indoor fan operate in a heat pump system?
  • What can frequent cycling of a heat pump indicate?
  • In the refrigeration cycle, what occurs during the compression stage?
  • During cooling mode, where does hot gas leave the compressor first flow to?
  • What safety mechanism prevents compressor damage during low outdoor temperatures?
  • Which innovation may be found on new high efficiency heat pump units?
  • What does "reversibility" refer to in heat pumps?
  • A customer reporting periodic cool air during heating mode may be experiencing what issue?
  • What component of a heat pump is responsible for transferring heat?
  • During the initial setup of a heat pump, which factor is most crucial for maintaining system efficiency?
  • What happens to the heat pump when the outdoor fan is not operational?
  • Why is it sometimes inadvisable to connect a standard gauge manifold set to a heat pump immediately?
  • What effect does improper installation of a heat pump have on its efficiency?
  • What can cause frost accumulation on the outdoor coil of a heat pump in heating mode when the ambient temperature is 45°F?
  • What is the temperature difference between the 1st and 2nd bulbs for heating on a heat pump thermostat?
  • Which component primarily allows air-source heat pumps to extract heat from outside air?
  • When troubleshooting a "no heat/no cooling" issue in a split system heat pump, what does the operation of the indoor fan verify when the thermostat is turned to the fan on/cool position?
  • What does COP stand for in heating systems?
  • What defines a "split system" heat pump?
  • What instrument is essential for checking the refrigerant charge in a heat pump system?
  • In heating mode, what is the pressure condition of the refrigerant in the indoor coil?
  • What type of defrost control is commonly employed in heat pumps?
  • How does a water-source heat pump differ from other types of heat pumps?
  • Why is proper ductwork design crucial in heat pump systems?
  • Which maintenance task is critical for maintaining heat pump efficiency?
  • How long approximately do the DTC N.O. contacts stay closed during the switching process to heat mode?
  • Which components make up a typical heat pump system?
  • What is an important consideration for the placement of a heat pump?
  • What type of compressor allows for continuous operation during cooling and heating cycles?
  • If an R-410A heat pump has a suction pressure of 131 PSIG and you add 2 PSIG for pressure drop, what is the true outlet pressure?
  • What is the primary purpose of the defrost relay in a heat pump?
  • When the heat pump compressor has malfunctioned, what mode can the customer switch the system into?
  • What component allows a heat pump to maintain efficiency during varying outdoor conditions?
  • Some heat pump systems utilize a ______________ as a metering device?
  • Which component is responsible for energizing auxiliary heat during the defrost cycle?
  • During the defrost cycle, what typically happens to the outdoor fan?
  • To prevent liquid flood-back, a heat pump using a reciprocating compressor should be equipped with which component?
  • What is the operational mode of a heat pump that moves heat from a cool space to a warmer space?
  • What are the environmental concerns associated with refrigerants?
  • How does the reversing valve function in a heat pump?
  • Which component in a heat pump is responsible for changing refrigerant from a liquid to a gas?
  • Which refrigerant is commonly used in high efficiency heat pump systems?
  • When do the positions of the N.O. and N.C. switches change in a time initiation/temperature termination defrost?
  • What role does airflow play in heat pump effectiveness?
  • What is one common troubleshooting technique for low airflow in a heat pump system?
  • What typically happens if insulation is inadequate in a heat pump system?
  • What type of vapor is contained in the suction line entering the compressor in heat mode?
  • What is the role of the indoor coil during the cooling cycle?
  • Which condition is indicated by a normal pressure reading when switched to cooling mode?
  • In addition to heat from the outdoor coil, what other source does a heat pump utilize in heating mode?
  • What does the coefficient of performance (COP) measure in heat pumps?
  • Which of the following is NOT a mode of operation for heat pumps?
  • What is the importance of vent placement in heat pump systems?
  • During the heating cycle, what function does the outdoor coil serve?
  • When installing a heat pump outdoor unit, what must be considered regarding drainage?
  • What is the recommended CFM across the evaporator coil of a heat pump?
  • For optimal efficiency, where should the air-to-air heat pump outdoor unit be located?
  • What measurement can indicate the effectiveness of a heat pump's defrost cycle?
  • How do compressors designed for heat pumps differ from those designed for air conditioning?
  • What regulates the operation of auxiliary electric heat based on outdoor temperatures?
  • What is a common method for mechanically troubleshooting a reversing valve?
  • What principle governs the operation of a heat pump?
  • In ductless heat pump systems, what is a common issue that might require troubleshooting?
  • What is the most likely cause if the outdoor coil is frozen solid during a "no heat" service call?
  • What is a common method to determine if auxiliary heat is needed?
  • What does the term "emergency heat" refer to in heat pump systems?
  • What is a disadvantage of air-source heat pumps?
  • What should a technician teach the customer to do with a night setback digital thermostat?
  • What happens to the heat pump's efficiency as outdoor temperatures drop for air-source models?
  • What does the term "thermal conductivity" refer to in the context of heat pumps?
  • Why is it important to monitor refrigerant levels in heat pumps?
  • What does an HSPF rating indicate?
  • In heating mode, when the outdoor fan shuts off during defrost, what is the primary goal?
  • What is the approximate temperature of air provided by air-to-air heat pumps without auxiliary heat?
  • What is the main purpose of the reversing valve in a heat pump system?
  • What design must liquid line filter-driers have if used on a heat pump system without check valves?
  • How is off-cycle crankcase heat provided in heat pumps?
  • What is the compression ratio for an R410A heat pump with a suction pressure of 50 PSIG and a head pressure of 285 PSIG?
  • During which mode is the reversing valve most critical for proper heat pump operation?
  • In Dual Fuel Systems, where must the indoor coil be located?
  • What is the most common complaint of customers transitioning from gas heat to a heat pump?
  • What role does a compressor play in a heat pump system?
  • What additional component is included in heat pump systems with a thermostatic expansion valve at each coil?
  • How is the DFR kept organized when the DTC N.O. contacts open?
  • When is a heat pump system considered to be efficiently operating?
  • How does zoning enhance the efficiency of heat pump systems?
  • The actuating components of a reversing valve in a heat pump include which two elements?
  • What is the most preferred method of charging any heat pump system in the field?
  • What does "enthalpy" refer to in HVAC systems?
  • What is the most common method of defrosting the outdoor coil on an air source heat pump?
  • In heating mode, what is the superheat if the suction line temperature at the evaporator outlet is 57°F?
  • What is a good service practice when installing a reversing valve?
  • What can the technician manipulate on the heat pump to simulate the defrost cycle?
  • What does "stratification" refer to in the context of heat pumps?
  • What is the significance of maintenance plans for heat pumps?
  • How does ground temperature influence geothermal heat pumps?
  • What is a ground loop in a geothermal heat pump?
  • What is the role of the heat exchanger in a heat pump?
  • What device is used for refrigerant metering in the heating cycle of a heat pump system?
  • Explain the term "latent heat" as it relates to heat pumps.
  • How can heat pumps affect energy bills?
  • During a defrost cycle, how long is auxiliary heat typically activated?
  • What does the acronym "BTU" represent in relation to heat pumps?
  • What kind of control systems are commonly used with heat pumps?
  • What should you do if you find a temperature split of 29°F in cooling mode?
  • Where should room thermostats for heat pumps be installed?
  • What is the main advantage of a geothermal heat pump over an air-source heat pump?
  • What condition does the suction line at the compressor typically exhibit when the heat pump is operating in heat mode?
  • What should be checked if a compressor is not starting in a heat pump system?
  • What is the term for the outdoor temperature at which the heat pump offsets the heat loss of the conditioned space?
  • If the indoor fan operates at excessive speed in cooling mode, what issue may arise?
  • When manufacturer specifications are unavailable, how is CFM through a coil best calculated?
  • How is the movement of the piston in the reversing valve achieved?
  • What happens first when a heat pump unit switches to heat mode?
  • How can the performance of a heat pump be effectively monitored?
  • Before connecting a manifold gauge set to a heat pump system, what should you verify?
  • High suction pressure and low discharge pressure in a heat pump system may indicate what issue?
  • In most air-to-air heat pump systems, what is true about the indoor and outdoor coils?
  • What happens to auxiliary heat during the defrost mode if there is a faulty defrost relay?
  • What is one of the main benefits of a heat pump compared to traditional heating systems?
  • Where is the indoor coil typically mounted in relation to the auxiliary electric heat strips?
  • What should be the condition of a heat pump during a cold winter day?
  • How does a heat pump differ fundamentally from traditional heating systems?
  • What does the "defrost cycle" in heat pumps accomplish?
  • Which of the following can decrease the efficiency of a heat pump?
  • Which component is crucial for the longevity of a heat pump's reciprocating compressor?
  • What is the primary function of the compressor in a heat pump?
  • In high efficient heat pump systems using R-410A refrigerant, what metering devices are typically used?
  • What unit is used to rate heat pump mode efficiency?
  • Heat pumps are generally designed to work effectively at what type of ambient conditions?
  • What is the primary function of a heat pump during its defrost cycle?
  • When the modes of a heat pump are reversed, what happens to the refrigerant at the coil serving as the condenser?
  • Where is an outdoor ambient thermostat typically set?
  • What component is primarily responsible for changing the direction of refrigerant flow in a heat pump?
  • During the defrost cycle, which mode does the system switch to?
  • What factors should be considered when sizing a heat pump system for a building?
  • The use of a scroll type compressor in a heat pump can eliminate the need for which component?
  • What is the main advantage of ground-source (geothermal) heat pumps compared to air-source systems?
  • How does demand defrost differ from timed defrost?
  • What is a characteristic of a scroll type compressor in terms of liquid flood-back?
  • Air-to-air heat pumps are most practical to operate in areas where the lowest winter temperature does not go below ______ *F?
  • What is the role of insulation in a heat pump system?
  • When sizing a heat pump for both heating and cooling, what is primarily used for sizing?
  • In a heating system, what is the role of the reversing valve?
  • What can initiate the defrost cycle in a heat pump system?
  • How does humidity affect the performance of heat pumps?
  • What does "over-sizing" mean in the context of heat pump installations?
  • Which control operates the first stage of secondary heat in a heat pump?
  • How do energy efficiency ratings influence consumer choices in heat pumps?
  • What is the industry standard for deep vacuum in HVAC systems?
  • How does refrigerant flow through the compressor in a heat pump?
  • What is the COP (Coefficient of Performance) of electric resistance heat?
  • What is the preferred method for adjusting the refrigerant charge in a heat pump system?
  • Why is regular maintenance crucial for heat pumps?
  • What action can improve system performance if the indoor coil temperature split is unfavorable?
  • What is the purpose of a backup heating system in a heat pump?
  • What is a characteristic of electronic expansion valves used in some heat pumps?
  • How do air-source heat pumps function in extremely cold temperatures?
  • What is the role of dampers in a heat pump system?
  • Where is the LLP located in a heat pump system?
  • What feature may a high-efficiency heat pump have for low ambient conditions below 10°F?
  • What is the primary purpose of a heat pump?
  • When operating in heat mode, where does hot gas leave the compressor first flow to?
  • How does a heat pump's performance change with fluctuating outdoor temperatures?
  • Which component is energized through TH-1 when switching to heat mode?
  • What kind of valve is common in heat pump systems for controlling refrigerant flow in relation to capacity?
  • How does ambient temperature affect the efficiency of heat pumps?
  • What is a refrigerant leak, and why is it a concern?
  • What temperature setting can be expected for an outdoor ambient thermostat to ensure optimal performance?
  • What is a major component that distinguishes a heat pump from an air conditioning system?
  • What is the principal advantage of an air-to-air heat pump in warmer conditions?
Subscribe